Know where your electricity goes. And what it costs.
Monitoring built around your property and the questions you want answered.
From a heat pump at home to refrigeration in a restaurant, optional metering helps you understand where electricity goes, what it costs and how solar and batteries contribute.
Illustrations explain the monitoring concept, not installation wiring. Costs and savings depend on reading coverage and your tariff. Load-level solar and battery contributions are calculated estimates, not separate measurements of where each unit of electricity came from.
BUILT AROUND YOU
Your property. Your priorities.
Homes & apartments
Understand heating, EV charging and other large electrical loads.
Businesses & hospitality
Explore refrigeration, kitchens, heating and equipment across your premises.
Farms & larger sites
Plan monitoring around pumps, machinery, multiple buildings and three-phase supplies.
The right meter and number of channels depend on your supply, circuits and site layout. Only selected circuits are measured individually.
FREE IS A GREAT START. GO FURTHER WHEN YOU WANT.
More detail, on your terms.
Your community access stays free. Energy Expert adds optional equipment and a closer view of your energy; it does not take away your free features.
What you get
PV Pros Free
Energy Expert
Community & your profile
Included for everyone
Still included
Energy & financial insights
From supported inverter data and your tariff
Adds independent meter readings where installed
Weather & PVPal guidance
Where your location and data support it
Guidance informed by the extra readings available
Main electricity supply
From supported connected data sources
Independent import and export measurement
Large electrical loads
Whole-property picture from available data
Individual readings for the circuits you choose to monitor
Equipment & commissioning
No hardware purchase required
Tailored equipment and installation or delivery, priced separately
Results depend on supported connections, reading coverage and accurate tariffs. Metered comparisons can highlight differences; they do not replace your supplier’s bill or guarantee savings.
YOUR PATH TO ENERGY EXPERT
Start with a question. Build the right picture.
No need to choose meter models yourself. Your answers and saved property details help shape the assessment, with PVPal available to explain the steps.
01
Tell us what matters
Choose what you want to understand and use your existing property profile.
02
Choose your loads
Name the equipment you want monitored. Add optional breaker details and photos of your board, meter cabinet and inverter.
03
Understand your plan and price
See suggested equipment and available cost estimates. Equipment, installation or delivery, and SIM options are considered separately; the final design and quote need review.
04
Choose how it gets installed
PV Pros installation and commissioning, or delivery to site for your own installer. Availability and scope are confirmed with your quote.
Meet the equipment · specifications & simple layout
For homes, businesses, hospitality, farms and larger sites. The supply and circuit layout determine the equipment, not the property name.
Gold: electricity. Blue dashed: measurement or data connection. Concept only: exact CT placement, protection, power wiring and communications require an installer’s design. Built-in cellular circuit meters can change this layout. A supported inverter cloud API is an alternative data path.
ADW310
Your main electricity supply
An independent view of grid import and export for a suitable single-phase supply.
Technical details & checks
220 V nominal; paired 20(100) A transformer input
Active energy accuracy class 1
85–265 V AC auxiliary supply
RS485, Wi-Fi and cellular are different ordering options
Confirm the exact cellular variant, paired CT, supply rating and position before all property branches.
The PV Pros ADW210 setup monitors the consumption of four individual loads you choose. Name each load to see its electricity use and estimated cost when readings and tariffs are available.
Technical details & checks
Manufacturer maximum: four three-phase or twelve single-phase circuits
RS485 Modbus RTU; external gateway for mobile data
Matched mA-output CTs and connector arrangement
85–265 V AC/DC auxiliary supply
PV Pros currently budgets conservatively for four circuits per unit. Higher single-phase capacity requires verified channel mapping, CTs and MDA support.
An AC multi-circuit option for commercial, farm and other larger installations.
Technical details & checks
Manufacturer maximum: eight three-phase or twenty-four single-phase circuits
RS485 Modbus RTU; certain variants include 4G
85–265 V AC/DC auxiliary supply
AMC200L has a display; exact suffix determines options
PV Pros budgets conservatively for eight circuits per unit. Confirm AC 8E3 variant, CT outputs, channel mapping and price. Other AMC200 families include DC products.
A gateway transports supported meter and inverter data. It does not measure electricity itself.
Technical details & checks
Cellular and other communication variants are available
RS485 connection to supported devices
Power arrangement depends on variant and coupling
MQTT support requires the appropriate model and configuration
One gateway may serve meters and an inverter only when protocol, register map, serial settings, addresses and cable route are compatible. Confirm power supply and MDA integration.
Catalogue 2026-11-04.1. Published capability does not confirm compatibility with a particular inverter, CT or MDA configuration. Final model suffixes and prices are confirmed during review.
A LITTLE MORE KNOWLEDGE. A LOT MORE POSSIBILITY.
What would you like to understand?
Create your free profile first. Your dashboard will have an Energy Expert button whenever you want a closer look.